Zymo-Seq RiboFree Total RNA Library Kit

Zymo-Seq RiboFree Total RNA Library Kit

Cat#NameSize
R3000SZymo-Seq RiboFree Total RNA Library Kit (6 preps) 6 Preps
R3000Zymo-Seq RiboFree Total RNA Library Kit (12 preps) 12 Preps

Documents

Protocol: 3000S

Protocol: 3000

Datasheet:

SDS (MSDS): R3000

Barcode Sequences Table:

Categories: , ,

Description

Highlights

  •  The Fastest & Easiest Total RNA-Seq Library Kit: Prepare stranded, RiboFree libraries from total RNA in 3.5 hours.
  •  Compatible with Any Organism: Probe-free technology depletes rRNA & Globin from any RNA source.
  •  The Most Accurate: Eliminate bias from rRNA depletion

Description

Zymo-Seq RiboFree Total RNA-Seq Library Kit is the fastest, easiest RNA-Seq library prep kit available to make stranded, total RNA libraries. The automation-friendly protocol minimizes hands-on time to generate sequencer-ready, stranded, indexed libraries depleted of rRNA and globin in as little as 3.5 hours.

Depletion of ribosomal RNAs (which can comprise as much as 90% of a total RNA sample) is completely integrated into the workflow, using a novel, probe-free technology that removes rRNA, globin, or any other over-abundant, repetitive transcript from any sample type or species.

RiboFree Universal Depletion is validated across biological kingdom and phyla, including human, rodent, plant, and various prokaryotes, as well as RNA from a wide range of sample types including cells, tissue, FFPE tissues, and whole blood, eliminating the need to select sample-specific modules for different sample types. Just one total RNA-Seq library prep kit to deplete them all.

Because the RiboFree Universal Depletion is probe-free, researchers using the Zymo-Seq RiboFree Total RNA Library Kit will avoid transcriptome profiling bias found in other methods. High concentrations of rRNA-binding oligonucleotides used in probe-based approaches also bind to a significant number of non-ribosomal targets. As much as 20% of the 20,000 protein-coding genes in the human genome are significantly biased by these methods.

In contrast, the probe-free depletion developed by Zymo Research uses only abundant pre-existing transcripts for mismatch-free enzymatic removal of rRNA and globin, resulting in minimal off-target effects as low as 1.8% in all protein-coding transcripts.

This total RNA-Seq library prep kit’s protocol is fragmentation-free and works with up to 2 ug of undepleted total RNA, down to 50 ng of undepleted total RNA, or as little as 5 ng of ribosome-depleted RNA samples. Pre-mixed reagents are ready-to-use at every step, eliminating the need for manual master-mix preparation. Everything needed to make sequencing-ready libraries, including indexing primers, SPRI beads, and magnetic bead stand are included in the kit. It’s RNA-Seq made simple.

Learn more

Equipment Required

Thermocycler, magnet stand*, and microcentrifuge.
*for a complimentary magnet stand, please contact tech@zymoresearch.com

Input Quality

Ensure RNA A260/A280 and A260/A230 ratios are ≥ 1.8, DNA-free, and PCR inhibitor-free for high-fidelity cDNA transcription and depletion

Maximum Input

5 µg

Minimum Input

100 ng

Processing Time

As little as 3.5 hours (RNA to indexed library)

Recommended Input

500 ng

Sample Input Material

RNA from any species

Sequencing

Libraries are stranded and compatible with all Illumina® sequencing platforms. The Read 1 sequence will be antisense to the RNA molecule of origin.

Q1: Do you sell the ribo depletion separately

Yes, please contact technical support tech@zymoresearch.com for ordering information.

Q2: Will this kit work with prokaryotes?

Yes, this kit will work with any organism. As long as your sample has rRNA, this kit will work.

Q3: My sample is lower than 100 ng, will this kit still work?

Lower sample inputs will require a longer incubation time during RiboFree Universal Depletion. Please refer to Appendix B for suggestions

“This is probably the best RNA-seq library preparation kit I’be used (and I have used many). It is very simple and gives clean, reproducible results at a very affordable price. I would highly recommend this product to anyone looking for a quicker and easier library preparation kit. Zymo has never let me down.”

– Galina (City of Hope)

 

“I think this kit is faster and simpler to do than the Truseq RNA library prep kit. It was easy enough that I tried it once and got a nice library prep, with a high concentration and I did not make any mistakes in my first try! I will definitely buy this kit and recommend it to others without a doubt.”

– Rafael (UC Berkeley)

 

“This RNA Library Kit was easy to use and recovered good efficiency.”

– Veronica L (CICY Mexico)

Cat#NameSize
D3004-4-10DNA Elution Buffer10 ml
D3004-4-50DNA Elution Buffer50 ml
W1001-1DNase/RNase-Free Water1 ml
W1001-10DNase/RNase-Free Water10 ml
D4084-10Select-a-Size MagBead Set 10 ml
D4084-50Select-a-Size MagBead Set 50 ml
E2003ZymoTaq PreMix (50 Rxns.) (2 x 625 µl)
E2004ZymoTaq PreMix (200 Rxns.) (8 x 625 µl)
R3001Zymo-Seq RiboFree Universal cDNA Kit 12 Preps
D3008Zymo-Seq UDI Primer Set (Indexes 1-12) 12 indexes
D3096Zymo-Seq UDI Primer Plate (Indexes 1-96) 96 indexes
R3004-1-6Zymo-Seq Wash Buffer 6 ml
R3004-1-48 Zymo-Seq Wash Buffer 48 ml
3DP-1002PCR Strip MagStand 1 unit
  • Catalog#: R3000S / R3000
  • Package Length (in Inches): 0 /12
  • Package Width (in Inches): 0 /9
  • Package Height (in Inches): 0 /10
  • Size: Sample / 12 Preps
  • Unit Standard: Metric
  • Volume Units: Milliliters